Showing 1–12 of 13 results
-

SKU: GF-TAC.FGD
Material: UV stabilised resin with fibreglass reinforcement
Customisable: No
Colours Available: Black, yellow or white
Slip resistance rating: P5
Luminance reflectance values:
Yellow: 47.65 (wet), 48.30 (dry)
White: 57.40 (wet), 61.82 (dry)
Black: 3.49 (wet), 4.75 (dry)
-

SKU: GF-TAC.FG
Material: UV stabilised resin with fibreglass reinforcement
Customisable: No
Colours Available: Black, yellow or white
Slip resistance rating:
P5
Luminance reflectance values:
Yellow: 47.65 (wet), 48.30 (dry)
White: 57.40 (wet), 61.82 (dry)
Black: 3.49 (wet), 4.75 (dry)
-

SKU: GF-TACPAD.ST
Material: Polyurethane
Customisable: No
Colours Available: Black or yellow
Compliance & Anti-Slip Safety:
– National Construction Code – Section D3.8
– Australian/New Zealand Standard 1428.1 2009 – Design for access and mobility – Design for access and mobility: General requirements for access – New building works
– Australian/New Zealand Standard 1428.4.1 2009 – Design for access and mobility – Means to assist the orientation of people with vision impairment: Tactile ground surface indicators
Slip Resistance
All tactile pads have been tested in accordance with AS4586:2013 Appendix A
Test Method: Wet Pendulum
Slip Resistance Value: 63
Slip Resistance Classification: P5
-

SKU: GF-TAC.ST.C
Material: Polished 316 stainless steel plate complete with stainless steel tactiles with high density Polyethylene inserts
Customisable: No
Colours Available: Silver with black insert
Compliance
– National Construction Code – Section D3.8
– Australian/New Zealand Standard 1428.1 2009 – Design for access and mobility – Design for access and mobility:
General requirements for access – New building works
– Australian/New Zealand Standard 1428.4.1 2009 – Design for access and mobility – Means to assist the orientation of people with vision impairment: Tactile ground surface indicators.
Slip Resistance
All stainless steel tactile’s have been tested in accordance with AS4586:2013 Appendix A
– Slip Resistance Value: 68
– Slip Resistance Classification: P5
-

SKU: GF-TAC.ST
Material: 316 Stainless steel
Customisable: No
Colours Available: Silver
Compliance
– National Construction Code – Section D3.8
– Australian/New Zealand Standard 1428.1 2009 – Design for access and mobility – Design for access and mobility:
General requirements for access – New building works
– Australian/New Zealand Standard 1428.4.1 2009 – Design for access and mobility – Means to assist the orientation of people with vision impairment: Tactile ground surface indicators.
Slip Resistance
All stainless steel tactile’s have been tested in accordance with AS4586:2013 Appendix A
– Slip Resistance Value: 68
– Slip Resistance Classification: P5
-

SKU: GF-TAC03ST
Material: Solid brass
Customisable: No
Colours Available: Brass
Details: CNC Machine with mill finish. Concentric ring top with smooth edges.
Compliance
National Construction Code – Section D3.8
Australian/New Zealand Standard 1428.1 2009 – Design for access and mobility – Design for access and mobility: General requirements for access – New building works
Australian/New Zealand Standard 1428.4.1 2009 – Design for access and mobility – Means to assist the orientation of people with vision impairment: Tactile ground surface indicators
Slip Resistance
All brass tactile’s have been tested in accordance with AS4586:2013 Appendix A
– Test Method: Wet Pendulum
– Slip Resistance Value: 68
– Slip Resistance Classification: P5
Luminous Contrast
Luminous contrast testing was carried out in accordance with AS 1428.1-2009 Appendix B;
– LRV Dry: 58.86
– LRV: Wet: 51.62
-

SKU: GF-TAC PVD.ST
Material: Solid 316 Stainless Steel with black PVD coating
Customisable: No
Colours Available: Black
Details: CNC Machine with mill finish. Concentric ring top with smooth edges.
Compliance
– National Construction Code – Section D3.8
– Australian/New Zealand Standard 1428.1 2009 – Design for access and mobility – Design for access and mobility: General requirements for access – New building works
– Australian/New Zealand Standard 1428.4.1 2009 – Design for access and mobility – Means to assist the orientation of people with vision impairment: Tactile ground surface indicators
Slip Resistance
All stainless steel tactiles have been tested in accordance with AS4586:2013 Appendix A
– Test Method: Wet Pendulum
– Slip Resistance Value: 68
– Slip Resistance Classification: P5
Luminous Contrast
Luminous contrast testing was carried out in accordance with AS 1428.1-2009 Appendix B
– LRV Dry: 7.17
– LRV: Wet: 4.37
-

SKU: GF-TAC06.ST
Material: Stainless Steel with Anti-Slip Carborundum Infill
Customisable: No
Colours Available: Black or yellow
Compliance
National Construction Code – Section D3.8
Australian/New Zealand Standard 1428.1 2009 – Design for access and mobility – Design for access and mobility: General requirements for access – New building works
Australian/New Zealand Standard 1428.4.1 2009 – Design for access and mobility – Means to assist the orientation of people with vision impairment: Tactile ground surface indicators
Slip Resistance
All stainless steel tactile’s have been tested in accordance with AS4586:2013 Appendix A
– Test Method: Wet Pendulum
– Slip Resistance Value: 72
– Slip Resistance Classification: P5
Luminous Contrast
Luminous contrast testing was carried out in accordance with AS 1428.1-2009 Appendix B
Yellow
– LRV Dry: 35.62
– LRV: Wet: 32.78
Black
– LRV Dry: 5.57
– LRV: Wet: 4.24
-

SKU: GF-TAC02.ST
Material: Solid 316 Stainless Steel
Customisable: No
Colours Available: Silver
Details: CNC Machine with mill finish. Concentric ring top with smooth edges.
Compliance
National Construction Code – Section D3.8
Australian/New Zealand Standard 1428.1 2009 – Design for access and mobility – Design for access and mobility: General requirements for access – New building works
Australian/New Zealand Standard 1428.4.1 2009 – Design for access and mobility – Means to assist the orientation of people with vision impairment: Tactile ground surface indicators
Slip Resistance
All stainless steel tactile’s have been tested in accordance with AS4586:2013 Appendix A
– Test Method: Wet Pendulum
– Slip Resistance Value: 68
– Slip Resistance Classification: P5
Luminous Contrast
Luminous contrast testing was carried out in accordance with AS 1428.1-2009 Appendix B;
– LRV Dry: 51.69
– LRV: Wet: 37.66
-

SKU: GF-TAC03P
Material: Solid Brass
Customisable: No
Colours available: Brass
Compliance
– National Construction Code – Section D3.8
– Australian/New Zealand Standard 1428.1 2009 – Design for access and mobility – Design for access and mobility: – General requirements for access – New building works
– Australian/New Zealand Standard 1428.4.1 2009 – Design for access and mobility – Means to assist the orientation of people with vision impairment: Tactile ground surface indicators
Slip Resistance
All brass tactile’s have been tested in accordance with AS4586:2013 Appendix A
Test Method: Wet Pendulum
Slip Resistance Value: 68
Slip Resistance Classification: P5
-

SKU: GF-TAC06C
Material: Stainless steel with anti-slip Carborundum infill
Customisable: Colours only
Colours Available: Black or yellow
Details: CNC Machine with mill finish.
Compliance & Anti-Slip Safety
National Construction Code: Section D3.8 – Access for people with a disability
Industry Standards: Our stainless steel tactile indicators meet the requirements of AS1428.1 and AS1428.4.1
Slip Resistance: Achieved a slip resistance classification of P5
Luminance Contrast: The light reflectance value (LRV) of the rubber inserts have been tested in accordance with AS1428.1-2009 Appendix B
-

SKU: GF-TAC02P
Material: Solid 316 Stainless Steel
Customisable: No
Colours available: Silver
Compliance & Anti-Slip Safety:
National Construction Code: Section D3.8 – Access for people with a disability
Slip Rating: P5. Our stainless steel tactile indicators meet the requirements of AS1428.1 and AS1428.4.1
Slip Resistance: Achieved a slip resistance classification of P5